Calgary Data Recovery A service of iCube Development (Calgary) Ltd.
Drive health

How to read a SMART report

Each line in a SMART report has four numbers, and most confusion comes from mixing them up. Here is what each one means and which one to watch.

Updated November 26, 2026

Is the drive acting up? If it clicks, freezes, keeps disconnecting or has files you can't open, don't run checks on it. Turn it off and start here instead.
IDAttributeValueWorstThresholdRaw
5Reallocated sectors100100100
9Power-on hours8484014,212
197Current pending sectors10010000
199Interface CRC errors20020003
Example reading. Made-up values, laid out the way DiskPrep shows them.

Normalized value and worst

The normalized value is the drive's own score for that attribute. Depending on the maker it usually starts at 100, 200 or 253, and lower is worse. Worst is the lowest score that attribute has ever reached.

Each manufacturer scales these scores its own way, so 100 on one brand isn't the same as 100 on another. Compare a drive with its own earlier reports, not with a different model.

Threshold

The threshold is the line the manufacturer set for that attribute. If the normalized value falls to the threshold or below, the drive considers that attribute failed. A threshold of 0 means the attribute is for information only.

Drives often show problems long before any value reaches its threshold. A drive can pass every threshold and still have sectors it can't read.

Raw value

The raw value is the underlying count or measurement. For reallocated sectors, pending sectors and CRC errors it is usually a plain count, and it is the number most technicians look at first.

For other attributes the raw value is packed in a maker-specific way. Some drives show huge raw numbers for read or seek errors that are normal for that brand. If a raw value looks alarming on an attribute these guides don't cover, don't read it as a count.

What to watch first

On a hard drive: reallocated sectors (5), current pending sectors (197), offline uncorrectable sectors (198) and interface CRC errors (199). On an SSD or NVMe drive: the wear estimate, spare capacity and media errors. Then compare with your last report.

Free, from our lab

DiskPrep shows the numbers. These guides explain them.

DiskPrep is the tool we built to check and prepare the drives recovered files go home on. Its SMART viewer reads SATA, NVMe and many USB drives and saves a report you can keep and compare. Free download for Windows.

About DiskPrep

Related drive health guides

Talk to a technician

Drive showing warnings?

Send us what the report says and what the drive is doing. If it holds files you need, we'll tell you whether to copy them now or leave it off, and what an evaluation costs, if anything.

Drop-off: Southcentre Executive Tower, #610 - 11012 Macleod Trail SE, Calgary. No appointment needed.

Get directions · Map and service area

Ask a recovery technician

Tell us what the drive reports and what you need from it.

We never share your details. They're used only to contact you about this recovery.

We reply during business hours: Monday to Thursday 8:00 AM to 6:00 PM, Friday 8:00 AM to 5:30 PM. Need us sooner? Call (587) 387-2346.