Why change matters
A drive with 8 reallocated sectors that has shown 8 for two years may be living with an old defect it dealt with long ago. A drive that went from 0 to 8 in a month is developing new ones. Same number, very different drive.
Keep a simple record
Save a report when the drive is new, or the first time you check it. Save another every few months, and after anything unusual: a drop, a move, a power outage, or the drive running hot.
DiskPrep suggests a filename with the drive model and the date, so reports sort in order. You can add your own reference too, such as "office backup drive".
What to compare
Put the two reports side by side and look for numbers that moved.
Compare these between reports
- Reallocated, pending and offline uncorrectable sectors (5, 197, 198): any increase.
- Interface CRC errors (199): any increase after you changed the cable or enclosure.
- On SSDs: how fast the wear estimate is climbing, and any drop in spare capacity.
- Temperature: whether it now runs hotter in the same place.
When a number goes up
If replaced or unreadable sectors are climbing, copy the files you care about to another drive now, while it still works normally, and plan to replace it. Copy them once, most important first, rather than again and again.
If the copy slows down, freezes or the drive disconnects, stop. That is the point where more reading can make things worse. Turn it off and talk to us before trying again.