Calgary Data Recovery A service of iCube Development (Calgary) Ltd.
Arrays, NAS units and servers

RAID, NAS and server recovery in Calgary

When a RAID or NAS goes down, everything on it goes with it. We copy every drive first, work out how the array was laid out, and rebuild it from the copies. Your original drives are never written to.

Process and costs · Recovery terms

Right now: If a rebuild is running or the array has dropped offline, don't start another one. Shut it down cleanly, leave every drive in its bay, and call us.

How arrays usually fail

One drive failed, then another during the rebuild

The most common RAID 5 loss. Rebuilding is hard work for drives that are the same age.

NAS won't mount the volume

Synology, QNAP, Buffalo and others. The data is often fine on the disks.

Controller failed or lost its settings

We can work out the layout from the drives themselves.

Volume deleted or re-initialized

Often recoverable if nothing new was written afterwards.

Server won't boot

Volumes and virtual machine disks inside the array can be rebuilt from images.

Drives pulled and reinserted out of order

Recoverable, as long as no rebuild was forced afterwards.

How we put it back together

  1. 01

    Image every drive

    Each drive is labelled and copied in full. Any failing drive is repaired first so it can be read.

  2. 02

    Work out the layout

    Drive order, stripe size and parity are worked out from the data on the disks.

  3. 03

    Rebuild from the copies

    The array is reassembled virtually. Your original drives are never written to.

  4. 04

    Recover and list

    Files are pulled and checked, and you get a list of what came back.

Lab notes

Why the second drive fails

Drives bought together tend to wear out together. When one fails, its neighbours are often close behind, and a rebuild reads every sector of every drive. That's exactly the moment a second weak drive gives out.

A rebuild onto the wrong disk, or with the drives out of order, writes parity over good data. That's the one mistake we can't always undo, so the safest thing you can do is stop and call.

Before you touch the array again

Do

  • Shut it down cleanly.
  • Label every drive with its bay number.
  • Note the RAID level and the NAS or controller model if you know them.
  • Bring every drive, including the ones marked failed.

Don't

  • Start or retry a rebuild.
  • Swap drives between bays.
  • Run file system repair on the volume.

What clients said

As an IT professional, I have been using and sending clients to iCube for years.
Kurt M., Google review
4.9400+ Google reviews
Read them

What people ask about RAID and NAS

Which RAID levels do you work with?

RAID 0, 1, 5, 6, 10, 50 and 60, on hardware controllers, software RAID and NAS units.

Do I need to bring the NAS box itself?

The drives are what matter. Bring the enclosure too if it's easy to carry; it can save time.

One drive failed but everything still works. What should I do?

Back it up before you replace anything. If you can't, call us before the rebuild starts.

Is the evaluation free for a RAID or NAS?

No. The free standard evaluation covers one device. Multi-drive arrays need more work to assess, so we quote the evaluation before we start.

My volume was encrypted. Can you still recover it?

Only with the password or key. Encryption does its job: without the key, nobody can read the data, including us. Have it ready when you call.

Evaluation

Tell us about the array

Send the details or call (587) 387-2346. We'll tell you what to do with it until you get here.

Drop-off: Southcentre Executive Tower, #610 - 11012 Macleod Trail SE, Calgary. No appointment needed.

Get directions · Map and service area

Request an evaluation

Array evaluations are quoted before we start. If we can't recover your files, you pay nothing for the recovery.

We never share your details. They're used only to contact you about this recovery.

We reply during business hours: Monday to Thursday 8:00 AM to 6:00 PM, Friday 8:00 AM to 5:30 PM. Need us sooner? Call (587) 387-2346.