| ID | Attribute | Value | Worst | Threshold | Raw |
|---|---|---|---|---|---|
| 199 | Interface CRC errors | 200 | 200 | 0 | 1,486 |
What it counts
Each block sent over the connection carries a check value. When the value doesn't match on arrival, the block is sent again and this counter goes up. The data stored on the drive isn't affected.
The count never goes back down. Errors from years ago stay in every report for the life of the drive, so what matters is whether it is still rising.
Common causes
The cause is almost always somewhere between the drive and the computer.
Usually one of these
- A loose, kinked or worn SATA cable.
- A failing USB enclosure, dock or adapter.
- A bad port, backplane or NAS bay.
- Unstable power to the drive.
What to do
On a drive that otherwise works normally, replace the cable or try a different port or enclosure, then save a new report after some use. If the count stops climbing, the connection was the problem. If it keeps going up with a new cable and port, the drive's own electronics may be at fault.
Frequent CRC errors can look like a failing drive: slow copies, freezes and dropouts. If that is happening and the drive holds files you need, stop and turn it off before swapping parts around.